S19 XP Hyd.

S19 XP Hyd.

Efficient hydro-cooled miner offering 257 TH/s hash rate at 5346W power for BTC, BCH, and BSV mining.

  • Hash rate: 257 TH/s
  • Electricity: 5346W
  • Minable coin: $BTC/BCH/BSV
  • Algorithm: SHA-256
  • Power Efficiency: 20.8 J/T
  • Cooling: Hydro-cooling

| Performance Curves


1. Hashrate vs. Inlet Coolant Temperature

2. Power Efficiency vs. Inlet Coolant Temperature

(1-1) The hashrate value, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power efficiency on wall fluctuate by ±5%.

| Specifications


 

Product Glance Value
Model S19 XP Hyd.
Crypto algorithm/coins SHA256 | BTC/BCH/BSV
Typical hashrate, TH/s(2-1) 257
Power on wall @35°C(2-2)Watt(2-1) 5346
Power efficiency on wall @35°C(2-2)J/T(2-1) 20.8
Detailed Characteristics Value
Power supply
Phase 3
Input voltage, Volt(3-1) 380~415
Input frequency range, Hz 50~60
Input max current, Amp 12
Hardware Configuration
Network connection mode RJ45 Ethernet 10/100M
Server size (length*width*height, w/o package), mm 410*170*209
Server size (length*width*height, with package), mm 570*316*430
Net weight, kg 12.8
Gross weight, kg 14.1
Environment Requirements
Inlet coolant temperature,  20~40
Coolant flow, L/min 8.0~10.0
Coolant pressure, bar ≤3.5
Working coolant(3-2) Antifreeze/ Pure water/Deionized water
Coolant  pH value
Antifreeze: 7.0~9.0
Pure water: 6.5~7.5
Deionized wate: 8.5~9.5
Diameter of coolant pipe connector, mm OD10
Storage temperature, °C -20~70
Operation humidity(non-condensing), RH 10%~90%

 

English
Scroll to Top